FTK9 Series |
|||
|
Features |
|
||
|
·
|
Small
converter size |
||
|
·
|
Close access to the target
|
||
|
·
|
Measuring range 600~2,000°C |
||
|
·
|
Linear selectable analog output |
||
|
·
|
Easy set-up using parameter setting unit PWC1
|
||
|
Description FTK9 series infrared thermometers employ fiber optic cable
designed for precise non-contact temperature measurement of otherwise
inaccessible or moving targets. Thermometer consists of a remote sensor
head, fiber optic cable and a converter unit. Infrared energy of the
target is passed on from the lens to the converter unit through a fiber
optic cable. The converter unit converts infrared energy into linear
analog output signal for convenient display or recording by external
devices like temperature indicator, controller, recorder or PLC. Analog
output scaling is possible. Optional computer interface is available.
Single point alarm output is provided.
Thermometer is equipped with a LED guide light for aiming at the target and for indication of the target spot size. It is also equipped with peak hold and smoothing function. |
|||
|
|
Reflection correction function is available in
case of error caused by target surface is reflecting any external energy. Sensor head and fiber optic cable can withstand ambient
temperature up to 150°C allowing close access to target for precise
temperature measurement under harsh environmental conditions. Length of
the fiber optic cable can be chosen to keep the converter unit safely away
from extreme environment. Converter unit also has robust design and work
well at ambient temperature of up to 70°C.
Parameter setting unit Various measurement parameters of thermometers such
as emissivity correction, temperature measurement mode, measuring range,
analog output scaling, alarm point and response time can be programmed
into the converter unit using parameter setting unit. |
||
|
Parameter
setting unit PWC1 |
|||
|
Model/
specifications |
FTK9-P300 |
FTK9-A600 |
||
|
Temperature
range |
300~2,000°C |
600~2,000°C |
||
|
Sensor |
InGaAs |
Si |
||
|
Spectral
response |
0.8~1.6
mm |
0.8~1.0
mm |
||
|
Minimum
spot size |
f1.8mm
at 100mm |
f4.0mm
at 300mm |
||
|
Target
spot/ distance |
To
be released |
f13mm
at 1,000mm f49mm
at 3,000mm |
||
|
Accuracy (at
emissivity = 1.0) |
Below
800°C: ±4°C 800~1,200°C:
±0.5% of the measured value 1,200~2,000°C:
±1% of the measured value |
|||
|
Repeatability |
±
0.2% of measured value ±2°C |
|||
|
Emissivity
correction |
Adjustable
from 0.050 to 1.0 in steps of 0.001 |
|||
|
Response
time |
Adjustable
from 0.001~600 seconds (95%) |
|||
|
Measuring
modes |
Peak
hold and smoothing |
|||
|
Target
sighting |
LED
marker indicating measured spot size |
|||
|
Analog
output |
Selectable
0~20mA, 4~20mA, 0~1V or mV/°C, 0~5V & 0~10V (option) |
|||
|
Digital
output (option) |
RS232C |
|||
|
Alarm
output |
Open
drain, single point |
|||
|
Sensor
head |
Aluminium
casing with 6mm lens |
|||
|
Fiber
optic cable |
0.2mmf
stainless steel shielded cable, 1 meter long (standard) |
|||
|
Ambient
temperature |
Sensor
head and fiber optic cable: 150°C, Converter
unit: 70°C |
|||
|
Ambient
humidity |
35~85%
rH, non-condensing |
|||
|
Power
supply |
4.7~27
VDC, 0.1 A max. |
|||
|
Dimensions
Sensor head
|
Converter
unit
|
|||
|
Typical
applications
|
|
|
||
|
|
|
|||
|
Temperature
measurement inside vacuum furnace |
Temperature
measurement of moving object |
|||